1.Meanings of Stereoview in Cerebral Angiogram
Yeungnam University Journal of Medicine 1985;2(1):53-57
Many pictures must be taken for the presumption of the stereorelation of the cerebral artery, which obtained with ordinary cerebral angiography. And it is very difficult to understand the stereoimage and required many experiences. But it is able to presume the stereorelationship in only brief eye's training without the aid of the stereoscope using the prism. For the stereoview, we need the paired angiograms obtained only straight and tilting the X-ray tube. In practice, with this stereoview in cerebral angiogram, we could know the directions of the aneurysmal neck and fundus with the stereorelationship of the cerebral artery and indeed helps us greatly in operation field. In addition, we might guess the location and stereorelationships of the feeding artery and draining vein in arteriovenous malformation and other vascular tumors and it was great aid in diagnosis and operation. Now we present the methods of the pictures for the stereoview in cerebral angiogram and the methods for eye's training.
Aneurysm
;
Arteries
;
Arteriovenous Malformations
;
Cerebral Angiography
;
Cerebral Arteries
;
Diagnosis
;
Neck
;
Veins
2.Complications of Subarachnoid Hemorrhage
Yeungnam University Journal of Medicine 1985;2(1):5-9
No abstract available.
Subarachnoid Hemorrhage
3.The cervical spinal fractures : comparison of the sites and incidences according to the causes and the types of the injuries
Jae Ho CHO ; Kil Ho CHO ; Woo Mock BYUN ; Sun Yong KIM ; Bok Hwan PARK
Yeungnam University Journal of Medicine 1993;10(1):114-126
The fractures of the cervical spine are relatively uncommon, but they may cause serious neurologic deficits temporarily or permanently. So, it is very important to treat the patients early by way of exact evaluation for the sites and the mechanisms of the injuries. The authors reviewed retrospectively 188 cervical spinal fractures in 100 patients from Sep. 1984 to Aug. 1990. Commonly involed levels were C5 and C6 in lower cervical level and C2 in upper cervical level and the sites in each spine were body; lamina and odontoid process. The hyperflexion injury was the most common type of the cervical spinal fractures occupying 53% of all cervical fractures and cause more multipe fractures(2.26 fractures/patient) than in hyperextension (1. 68 fractures/patient). In hyperflexion injuries, body, transverse and spinous process were commonly involved but lamina fracture was relatively common in hyperextension injury. The dislocations associated with fractures were developed most commonly in hyperflexion injury and 70% of these were anterior dislocation and the most commonly involved levels were C5-6 and C6-7. In conclusion, hyperflexion injury needs more close examination for the entire spinal levels than injuries of other mechanisms because it results in more severe fractures with or without dislocation and relatively frequent multiple fractures in different levels.
Dislocations
;
Humans
;
Incidence
;
Neurologic Manifestations
;
Odontoid Process
;
Retrospective Studies
;
Spinal Fractures
;
Spine
4.The comparision of NST, umbical artery velocimetry and amniotic fluid index in assessing the pregnancy outcomes of high risk pregnancies.
Yong Won PARK ; Jae Sang CHO ; Chan Ho SONG
Korean Journal of Obstetrics and Gynecology 1993;36(7):1364-1368
No abstract available.
Amniotic Fluid*
;
Arteries*
;
Female
;
Pregnancy
;
Pregnancy Outcome*
;
Pregnancy*
;
Rheology*
5.A scintigraphic study on the change of intrahepatic bile flow
Sung Ho CHOI ; Yong Il KIM ; Suk Shin CHO
Journal of the Korean Surgical Society 1991;40(3):304-313
No abstract available.
Bile
6.A scintigraphic study on the change of intrahepatic bile flow
Sung Ho CHOI ; Yong Il KIM ; Suk Shin CHO
Journal of the Korean Surgical Society 1991;40(3):304-313
No abstract available.
Bile
7.Embolization of carotid-cavernous fistula using a silicone balloon and a tracker catheter system
Sun Yong KIM ; Kil Ho CHO ; Bok Hwan PARK
Journal of the Korean Radiological Society 1992;28(1):36-41
With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in cases of small fistula, pseudoaneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitations, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients(silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing.
Aneurysm, False
;
Balloon Occlusion
;
Carotid Artery, Internal
;
Catheters
;
Fistula
;
Hand
;
Latex
;
Silicon
;
Silicones
8.Embolization of carotid-cavernous fistula using a silicone balloon and a tracker catheter system
Sun Yong KIM ; Kil Ho CHO ; Bok Hwan PARK
Journal of the Korean Radiological Society 1992;28(1):36-41
With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in cases of small fistula, pseudoaneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitations, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients(silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing.
Aneurysm, False
;
Balloon Occlusion
;
Carotid Artery, Internal
;
Catheters
;
Fistula
;
Hand
;
Latex
;
Silicon
;
Silicones
9.A Study on the Spectacles-wearing in Korea
Seung Hum YU ; Yong Ho LEE ; Woo Hyum CHO
Korean Journal of Preventive Medicine 1987;20(1):120-128
To assess the proportion of spectacles-wearing and an aspect of familial aggregation of myoptic spectacles-wearing and to observe the birth cohort for myoptic spectacles-wearing, a nationwide self-administered questionnaire survey was conducted from March 11 to September 19, 1985. A probability sample of 13,346 persons was taken from 180 enumerated districts designated by the fifth nationwide tuberculosis prevalence survey from Korean Institute of Tuberculosis. The major findings of this survey are as follows: 1) Total of 62.5% of the study population lived in urban area whereas 37.5% lived in Eup-Myun area. There was statistically significant difference in age and sex distribution between two residential area. 2) The percentage of spectacles-wearing was 8.3% and among these, myoptic and hyperoptic spectacles were 6.0%, 2.3%, respectively. A total of 8.8% of the male study population wore spectacles and this was slightly higher than the female (8.0%). 3) Among the occupational groups, students were the highest myoptic spectacles-wearing group whereas professionals were the highest hyperoptic spectacles-wearing group. 4) The proportion of myoptic spectacles-wearing was higher in female students than in male students respectively 11.6%, 8.7%. There was an increasing tendency of spectacles-wearing as age increased. 5) The age-sex adjusted prevalence rate of myoptic spectacles-wearing by residential areas was 2 times higher in urban area than Eup-Myun area. 6) A wearing of the myoptic spectacles in early age was observed in recent birth cohort than remote birth cohort. 7) There was a tendency of familial aggregation for myoptic spectacles-wearing. The proportion of myoptic spectacles-wearing was 6 times higher for those who had parents wearing spectacles. 8) 60.9% of the total myoptic spectacles-wearing persons received the eye-specialist's order and 44.9% for the hyperoptic spectacles wearing.
Cohort Studies
;
Eyeglasses
;
Female
;
Humans
;
Korea
;
Male
;
Occupational Groups
;
Parents
;
Parturition
;
Prevalence
;
Surveys and Questionnaires
;
Sampling Studies
;
Sex Distribution
;
Tuberculosis
10.Conservative Treatment of Anterior Cruciate Ligament Rupture.
Woo Shin CHO ; Sung Il BIN ; Yong Sun CHO ; Young Kil HAN ; Ho In CHA
The Journal of the Korean Orthopaedic Association 1997;32(2):282-287
Between August 1994 and June 1995, seventeen patients diagnosed as having partial or complete ruptures of the anterior cruciate ligament on MRI were managed by non-operative methods. Among them four patients were excluded due to operation during follow-up and the results were evaluated at a one year follow-up. We selected the patients prospectively for non-operative care using the selection criteria of age, degree of instability, activity level and patient compliance. The average age of them was 37.7 years. Initially knee stress test and MRI were checked, and Cybex study and Lysholm knee scoring were done at post-trauma one year follow-up. They were managed conservatively by ROM and muscle strengthening exercises and a brace fitting schedule for three months. Among them, six cases had partial tears and seven had a complete tear initially. At the one year follow-up, five of six cases who had shown partial ruptures, and two of seven cases with complete tears, recovered continuity of the ruptured ACL on MRI. Their Lysholm knee score was 84.4, and the Cybex test showed no difference in muscle power between the injured and uninjuried side. Those patients who had loss of continuity on follow-up MRI showed Lysholm score of 57.4 and decreased muscle power on Cybex study. Although there are still controversies about the adequate management of ACL injuries, our study suggests that conservative management is a viable alternative to surgery as long as the patients are selected prudently. For more concrete results, however, careful analysis based on a longer follow up period is necessary.
Anterior Cruciate Ligament*
;
Appointments and Schedules
;
Braces
;
Exercise
;
Exercise Test
;
Follow-Up Studies
;
Humans
;
Knee
;
Magnetic Resonance Imaging
;
Patient Compliance
;
Patient Selection
;
Prospective Studies
;
Rupture*